Shenzhen Jutai Comm Co., Ltd.

J - Journey U - Unrivaled T - Tech A - Advancement I - Innovation

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Loop Detector /

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Contact Now
Shenzhen Jutai Comm Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MrNorman
Contact Now

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Ask Latest Price
Video Channel
Brand Name :JUTAI
Model Number :LD-100
Certification :CE
Place of Origin :China
MOQ :1
Price :Negotiable
Payment Terms :T/T, L/C, D/A, D/P, Western Union, Paypal, , MoneyGram, Alipay
Supply Ability :10000pcs/month
Delivery Time :3-5 working days after receipt the payment
Packaging Details :Carton Parcking(13.5*8.5*5cm)/0.3kg/unit
Power Supplu :110-240v
Sensitivity Range :20-2000μH
Sensitivity Setting :6 way selectable/Highest0.010%DL/L/ Lowest 2.56%DL/L
Frequency :Four step switch selectable20-80KHz
Operation Tempts :-40℃ to +70℃ / (-111°F to +158°F)
Fault Output :Blinks slowly: may indicate a short circuit or insufficient number of turns
Blinks faster: may indicate an open loop or excessive number of turns
Response Times :Turn-on 10-90MS / Turn-off 10-90MS
Relay :Presence relay / Fault relay
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector
Product Description:
  1. Introduction:
    • The Parking Barrier Gate Loop Detector is a sensor designed specifically for parking barrier gates, capable of efficiently identifying and detecting all types of vehicles, including oversized vehicles, trucks, motorcycles, and more, ensuring automatic gate opening and closing.
  2. Features:
    • Single Channel Vehicle detector.
  3. Advantages:
    • Wide Sensing Range and High Sensitivity: with a sensing range from 15 to 2000μH and high sensitivity, it accurately detects various vehicles, ensuring reliable detection performance.
    • Automatic Reset Function: the sensor automatically resets in case of a malfunction, eliminating the need for manual intervention and enhancing system stability and reliability.
    • Multiple Detection Level Selection: featuring 16 selectable levels ranging from 0.008% DL/L to 2.50% DL/L, it can be adjusted according to specific requirements, suitable for different application scenarios.
    • 40000V Lightning Protection: equipped with robust 40000V lightning protection, it effectively safeguards the sensor against damage from lightning strikes.
    • Wide Operating Environment Range: suitable for a wide range of operating environments, with a temperature range from -40°C to +70°C, ensuring stable operation even in harsh weather conditions.

Indicates and Switch:

  • Power Led: RED power LED indicates "Power ON".
  • Detecting Led:
    • Continuously On: Indicates vehicle detection.
    • Blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
    • Blinking fast: Indicates loop is open circuit or too many twists after the loop.
  • Switch 1 (Trimpot), Sensitivity Selection:
    • Sensitivity of the loop can be adjusted by the trimpot labeled "Sensitivity". User can select 16 different settings by turning the trimpot with 0 being the least sensitive and "F" being the most sensitive.
  • Switch2 (Dipswitch Settings):
    • DIP1 & DIP2 Setting Special Functions:
      • DIP1 ON: Output has 2 seconds delay. (No relay output if the vehicle speed is over 8km/h).
      • DIP2 ON: Increase sensitivity to avoid unwilling relay off for leaving vehicle especially for trailer.
    • DIP3 & DIP 4 Setting Relay B Output:
      DIP MODE Relay B Output Loop Coils Status_L
      OFF OFF When vehicle is moving out, output for relay B is 200m/s Relay B Output Type_
      ON OFF When the vehicle has left, output for relay B is 600m/s Relay B will be present output. No Relay B Output Type_
      ON ON Can be used to test the Loop. If the loop is faulty, Relay B will be on and it will switch off once the fault is fixed.
    • DIP 5 Setting Automatic Reset:
      DIP MODE Present Mode
      ON Vehicle can be permanently present (no auto - reset, unless vehicle has left or manual reset)
      OFF Normal mode (automatic reset after 30 minutes present of vehicle, used to solve the mistake operation. If it is recommended)
    • DIP6 & DIP7 & DIP 8 Setting Relay ADelay:
      DIP MODE Delay AOutput
      OFF OFF OFF 0 sec Output
      ON OFF OFF 2sec Output
      OFF ON OFF 5sec Output
      ON ON OFF 8 sec Output
      OFF OFF ON 10 sec Output
      ON OFF ON 15 sec Output
      OFF ON ON 20sec Output
      ON ON ON 30 sec Output
    • DIP9 & DIP 10 Setting Frequency (40 K to 100 KHz):
      DIP MODE Frequency
      OFF OFF High
      ON OFF Medium - High
      OFF ON Medium - Low
      ON ON Low
      • In the application, where two or more loop detectors and sensing loops have been installed, set one detector to high frequency and the other set to low frequency to minimize the effects of cross - talk between the two systems (The sensing loops and detectors should be positioned at least 2m apart).
  • Reset Button: Please note: The LD - 100 must be reset every time a setting change is made to the Dip switches.

Detector position and installation:

  • Install the detector in a weatherproof housing.
  • The detector should be as close to the sensing loop as possible.
  • The detector should always be installed away from strong magnetic fields.
  • Avoid running high voltage wires near the loop detectors.
  • Do not install the detector on vibrating objects.
  • When the control box is installed within 10 metres of the loop, normal wires can be used to connect the control box to the loop. More than 10 metres requires the use of a 2 core shielded cable. Do not exceed 30 metres distance between control box and loop.

Loop Installation:

  • The loops are sealed using a "quick - set" black epoxy compound or hot bitumen mastic to blend with the roadway surface.
  • Loop perimeter and Cylinder numbers:
    Loop perimeter Cylinder numbers
    3 - 4M 6
    4 - 6M 5
    6 - 10M 4
    10 - 20M 3
    20M - UP 2
  • TroubleShooting:
    • If the detector is not working: Press reset.
    • If red led indicator is not fully lit: Check for power supply.
    • If green led indicator:
      • Blinks slowly: It maybe because the loop is short circuit or the no: of turns is not enough.
      • Blinks faster: It maybe because the loop is open or the no: of turns is too many.
    • If no: of turns is not enough: Lower the frequency (if the frequency is still to high, you must add more turns).
    • If no: of turns is too many: Higher the frequency (if the frequency is still to low, you must remove some turns).

Product parameters:

Specification Value
Self-turning Range 20-2000μH
Sensitivity 16-way selectable / Highest 0.010% DL/L / Lowest 2.56% DL/L
Frequency Four-step switch selectable 20-80KHz
Power Requirements 110-240VAC (48 to 62Hz)
Operation Temp -40℃ to +70℃ / (-111°F to +158°F)
Fault Output Blinks slowly: may indicate a short circuit or insufficient number of turns <br> Blinks faster: may indicate an open loop or excessive number of turns
Response Times Turn-on 10-90MS / Turn-off 10-90MS
Visual Indications Power LED - Red <br> Channel LED - Green
Reset Reset by push button on the front of the enclosure
Relay Output Presence relay / Fault relay
Humidity Up to 95% relative humidity without condensation

Switch 2 (Dipswitch Settings)

1.DIP 1 & DIP 2 Setting Special Functions

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

2.DIP 3 & DIP 4 Setting Relay B Output

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

3. DIP 5 Setting Automatic Reset

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

4. DIP 6 & DIP 7 & DIP 8 Setting Relay A Delay

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

5. DIP 9 & DIP 10 Setting Frequency (40 K to 100 KHz). Used to avoid the interference

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Loop Installation:

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Trouble Shooting:

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Compared to other brands

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Mass Production:

Our production line ensures efficient mass production, rigorous quality control, and thorough pre-shipment testing to deliver Loop detector products of the utmost perfection.

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector


Certification:

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector

Inquiry Cart 0